AIR HANDLING

FAN COIL UNIT

Complete your offshore air conditioning system with the reliable HI AIR KOREA(HAK) FAN COIL UNIT!

HAK has developed different types of customizable FAN COIL UNIT in response to the highly demanding room air requirements for use in offshore applications.

HAK FAN COIL UNIT is composed of filter, fan, cooling coil and heating coil in compact casing.

It can deliver the right amount of conditioned air at any load at low noise level for additional comfort.

Together with the other HAK air conditioning equipment, these HAK FAN COIL UNITs are your partners for bringing quality air into your environment.

  • FEATURES

    SELECTION

    • Extensive range of cooling capacities from 3 USRT to 20 USRT
    • Customized design for offshore applications

    CONSTRUCTION

    • Simple and compact designed for onboard space limitations
    • Stainless steel casing(SS304 / SS316) with single skin
    • Mineral wool insulation
    • High quality integrated components for maximum reliability
      • The fan’s mounting ensures low level of noise and vibrations
      • Built in directly coupled centrifugal fan with motor
      • Washable flat filter is placed in front of the evaporator
      • Copper tube with copper fins cooling coil
    • Cooling medium : HFC refrigerants(R-404A, R-407C, R-134a), Chilled water
    • Power supply : 380/440/690Vac, 50/60Hz, 3-phase
    • Starter : Mounted on the front door(temp. indicator, push buttons, indicating lamps)
    • Factory assembled, tested under strict quality standards

    MAINTENANCE

    • Easy installation and maintenance
  • OPTIONS
    • Stainless steel casing(SS316L) with double skin and coating
    • Flexible connections and counter flanges for air intake and outlet
    • Dampers for fresh and return air intake
    • Electric heating coil / Steam heating coil
    • 2-way or 3-way control valve for chilled water cooling coil
    • Other refrigerants are available
  • CAPACITIES

    CAPACITY & DIMENSIONS(STANDARD)

    (Design basis : Air inlet 27 ℃ RH 50 %, Air outlet 15 ℃ RH 90 %)_R-407C

    MODEL CAPACITY AIR FLOW
    RATE
    Ext. STATIC PRESSURE POWER
    INPUT
    DIMENSION
    (mm)
    MIN.SERVICE SPACE
    (mm)
    (kW) (㎥/h) (Pa) (kW) WIDTH HEIGHT DEPTH FRONT RIGHT LEFT REAR
    GRILLE INLET / GRILLE OUTLET
    HIF-03G** 10.5 1,800 N/A 0.25 1,000 1,750 600 1,000 500 300 300
    HIF-05G** 17.4 2,400 N/A 0.25 1,000 1,750 600 1,000 500 300 300
    HIF-08G** 25.6 3,360 N/A 0.35 1,200 1,930 700 1,000 500 300 300
    HIF-10G** 34.9 5,100 N/A 0.50 1,400 2,100 750 1,000 500 300 300
    HIF-15G** 52.3 7,200 N/A 0.70 1,600 2,100 900 1,000 500 300 300
    HIF-20G** 69.7 9,600 N/A 2.2 1,700 2,430 900 1,000 500 300 300
    DUCT INLET / DUCT OUTLET
    HIF-03D** 10.5 1,800 350 0.55 1,000 1,520 600 1,000 500 300 300
    HIF-05D** 17.4 2,400 350 0.55 1,000 1,520 650 1,000 500 300 300
    HIF-08D** 25.6 3,360 350 1.5 1,200 1,800 700 1,000 500 300 300
    HIF-10D** 34.9 5,100 350 2.2 1,400 2,250 750 1,000 500 300 300
    HIF-15D** 52.3 7,200 350 4.4 1,600 2,300 900 1,000 500 300 300
    HIF-20D** 69.7 9,600 350 4.4 1,700 2,350 900 1,000 500 300 300
    GRILLE INLET / DUCT OUTLET
    HIF-03M** 10.5 1,800 350 0.55 1,000 1,520 600 1,000 500 300 300
    HIF-05M** 17.4 2,400 350 0.55 1,000 1,520 650 1,000 500 300 300
    HIF-08M** 25.6 3,360 350 1.5 1,200 1,800 700 1,000 500 300 300
    HIF-10M** 34.9 5,100 350 2.2 1,400 2,150 750 1,000 500 300 300
    HIF-15M** 52.3 7,200 350 4.4 1,600 2,200 900 1,000 500 300 300
    HIF-20M** 69.7 9,600 350 4.4 1,700 2,350 900 1,000 500 300 300