(Total 28)
NO | CLIENT | HULL NO | SIZE | SHIP TYPE | OWNER | COUNTRY | SUPPLY SCOPE |
---|---|---|---|---|---|---|---|
28 | HHI | P110 | 8,000 TON | AEGIS DESTROYER | ROK NAVY | KOREA | Chiller : 250 USRT - 4 sets FCU : 76 sets Unit Cooler : 15 sets Fan : 59 sets NBCD : 4 sets |
27 | HHI | P122 | 8,000 TON | AEGIS DESTROYER | ROK NAVY | KOREA | Chiller : 250 USRT - 4 sets FCU : 76 sets Unit Cooler : 15 sets Fan : 59 sets NBCD : 4 sets |
26 | HHI | P123 | 2,500 TON | FRIGATE | ROK NAVY | KOREA | Chiller : 120 RT - 3 sets FCU : 24 sets Unit Cooler : 6 sets Fan : 26 sets NBCD : 4 sets Ref. Plant : 1.5 RT - 2 sets Pneumatic Damper : 20 sets |
25 | HHI | P133-4 | 2,500 TON | FRIGATE | ROK NAVY | KOREA | Chiller : 120 RT - 3 sets FCU : 24 sets Unit Cooler : 6 sets Fan : 26 sets NBCD : 4 sets Ref. Plant : 1.5 RT - 2 sets Pneumatic Damper : 20 sets |
24 | HHI | P135 | 6,000 TON | INTELLIGENCE SHIP | ROK NAVY | KOREA | Chiller : 160 RT - 2 sets Chiller : 60 RT - 2 sets FCU : 31 sets Fan : 24 sets NBCD : 3 sets Ref. Plant : 2 RT - 2sets |
23 | HHI | P141-2 | 400 TON | MIDGET SUBMARINE | ROK NAVY | KOREA | Fan : 2 sets |
22 | HHI | P154 | 10,000 TON | LOGISTIC SUPPORT VESSEL | ROK NAVY | KOREA | Chiller : 160 RT - 2 sets Chiller : 60 RT - 2 sets Chiller : 10 RT - 2 sets FCU : 38 sets Fan : 47 sets NBCD : 3 sets |
21 | HHI | P157 | 10,000 TON | LARGE TRAINING SHIP | ROK NAVY | KOREA | Chiller : 200 RT - 2 sets Chiller : 100 RT - 2 sets FCU : 42 sets Fan : 28 sets NBCD : 5 sets Ref. Plant : 2.5 RT - 2sets |
20 | HHI | P159-160 | 3,000 TON | FRIGATE | PHILIPPINES NAVY | PHILIPPINES | Chiller : 150 RT - 2 sets FCU : 26 sets Fan : 25 sets NBCD : 3 sets Ref. Plant :1.5 RT - 1sets |
19 | HHI | P161 | 3,000 TON | SUBMARINE | ROK NAVY | KOREA | Fan : 2 sets |
18 | HHI | P167 | 8,000 TON | AEGIS DESTROYER | ROK NAVY | KOREA | Chiller : 250 USRT - 4 sets FCU : 74 sets Unit Cooler : 10 sets Fan : 56 sets NBCD : 4 sets |
17 | DSME | 7029 | 8,000 TON | AEGIS DESTROYER | ROK NAVY | KOREA | Chiller : 250 RT - 4 sets FCU : 76 sets Unit Cooler : 15 sets Fan : 59 sets NBCD : 4 sets |
16 | DSME | H7044-7 | 12,000 TON | LOGISTIC SUPPORT VESSEL | UK NAVY | UK | Chiller : 256 RT - 3 sets AHU : 14 sets FCU : 16 sets Fan : 140 sets NBCD : 1 lot |
15 | DSME | H7048 | 13,000 TON | LOGISTIC SUPPORT VESSEL | NORWAY NAVY | NORWAY | Chiller : 342 RT - 3 sets AHU : 12 sets FCU : 40 sets Fan : 79 sets NBCD : 1 lot |
14 | DSME | H7716-7 | 3,000 TON | SUBMARINE | ROK NAVY | KOREA | Fan : 2 sets |
13 | DSME | H7721 | 3,000 TON | SUBMARINE | ROK NAVY | KOREA | Fan : 2 sets |
12 | HHIC | S138,152-154,164-167, S174-177, S182-185 | 600 TON | MISSILE PATROL SHIP | ROK NAVY | KOREA | Packaged A/C : 4 sets Fan : 8 sets |
11 | HHIC | S169-171 | 235 TON | Landing Craft Utility | ROK NAVY | KOREA | Packaged A/C : 1 sets Fan : 7 sets |
10 | STX | N1016-7 / N1024 | 2,500 TON | FRIGATE | ROK NAVY | KOREA | Chiller : 120 RT - 3 sets FCU : 24 sets Unit Cooler : 6 sets Fan : 26 sets NBCD : 4 sets Ref. Plant : 1.5 RT - 2 sets Pneumatic Damper : 20 sets |
9 | STX | N1026-7 | 800 TON | COASTAL PATROL VESSEL | COLOMBIA NAVY | COLOMBIA | Chiller : 30 RT AHU : 1 sets Fan : 22 sets |